Dependency:
See also: p1340
Note
The controller settings are also used in the current controller of the DC braking (refer to p1232).
p1346[0...n]
I_max voltage controller integral time / I_max_U_ctrl Tn
Access level: 3
Calculated: CALC_MOD_CON Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: DDS, p0180
Unit group: -
Unit selection: -
Function diagram: 6300, 7017
Min:
0.000 [s]
Max:
50.000 [s]
Factory setting:
0.030 [s]
Description:
Sets the integral time for the I_max voltage controller.
Dependency:
See also: p1340
Note
The controller settings are also used in the current controller of the DC braking (refer to p1232).
For p1346 = 0, the following applies:
The integral time of the I_max voltage controller is deactivated.
p1349[0...n]
U/f mode resonance damping maximum frequency / Uf res_damp f_max
Access level: 3
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: DDS, p0180
Unit group: -
Unit selection: -
Function diagram: 6310
Min:
0.00 [Hz]
Max:
3000.00 [Hz]
Factory setting:
0.00 [Hz]
Description:
Sets the maximum output frequency for resonance damping for U/f control.
Resonance damping is inactive above this output frequency.
Dependency:
See also: p1338
Note
For p1349 = 0, the changeover limit is automatically set to 95 % of the rated motor frequency - however, to a max. of
45 Hz.
p1400[0...n]
Speed control configuration / n_ctrl config
Access level: 3
Calculated: -
Data type: Unsigned32
Can be changed: T, U
Scaling: -
Dynamic index: DDS, p0180
Unit group: -
Unit selection: -
Function diagram: 6490
Min:
-
Max:
-
Factory setting:
0000 0000 0000 0000 1000
0000 0010 0001 bin
Description:
Sets the configuration for the closed-loop speed control.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Automatic Kp/Tn adaptation active
Yes
No
6040
05
Kp/Tn adaptation active
Yes
No
6040
15
Sensorless vector control speed precontrol
Yes
No
6030
16
I component for limiting
Enable
Hold
6030
18
Reserved
-
-
-
19
Anti-windup for integral component
Yes
No
6030
20
Acceleration model
ON
OFF
6031
22
Reserved
-
-
-
25
Acceleration torque instantaneous in the I/f mode
Yes
No
-