Dependency:
When p2111 is set to 0, the following is initiated:
- all of the alarms of the alarm buffer that have gone [0...7] are transferred into the alarm history [8...63].
- the alarm buffer [0...7] is deleted.
See also: r2110, r2122, r2123, r2124, r2125
Note
The parameter is reset to 0 at POWER ON.
p2112[0...n]
BI: External alarm 1 / External alarm 1
Access level: 3
Calculated: -
Data type: Unsigned32 / Binary
Can be changed: T, U
Scaling: -
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 2546
Min:
-
Max:
-
Factory setting:
1
Description:
Sets the signal source for external alarm 1.
Dependency:
See also: A07850
Note
An external alarm is triggered with a 1/0 signal.
r2114[0...1]
System runtime total / Sys runtime tot
Access level: 3
Calculated: -
Data type: Unsigned32
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: -
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the total system runtime for the drive unit.
The time comprises r2114[0] (milliseconds) and r2114[1] (days).
After r2114[0] has reached a value of 86.400.000 ms (24 hours) this value is reset and r2114[1] is incremented.
Index:
[0] = Milliseconds
[1] = Days
Dependency:
See also: r0948, r2109, r2123, r2125, r2130, r2136, r2145, r2146
Note
When the electronic power supply is switched out, the counter values are saved.
After the drive unit is switched on, the counter continues to run with the last value that was saved.
p2116[0...n]
BI: External alarm 2 / External alarm 2
Access level: 3
Calculated: -
Data type: Unsigned32 / Binary
Can be changed: T, U
Scaling: -
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 2546
Min:
-
Max:
-
Factory setting:
1
Description:
Sets the signal source for external alarm 2.
Dependency:
See also: A07851
Note
An external alarm is triggered with a 1/0 signal.
Parameters
7.3 Parameters
SINAMICS G120XA converter
580
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Summary of Contents for SINAMICS G120XA
Page 2: ......
Page 916: ...Index SINAMICS G120XA converter 914 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Page 917: ......