5.3
Preparing for commissioning
5.3.1
Collecting motor data
Data for a standard induction motor
Before starting commissioning, you must know the following data:
● Which motor is connected to the converter?
Note down the Article No. of the motor and the motor’s nameplate data.
If available, note down the motor code on the motor’s nameplate.
9ROWDJH
&XUUHQW
3RZHU
6SHHG
$UWLFOH1R
1(0$
1(0$
,(&
,(&
Figure 5-1
Example of the rating plate for a standard induction motor
● How is the motor connected?
Pay attention to the connection of the motor (star connection [Y] or delta connection [Δ]).
Note the appropriate motor data for connecting.
Commissioning
5.3 Preparing for commissioning
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
105