p0342[0...n]
Ratio between the total and motor moment of inertia / Mot MomInert Ratio
Access level: 3
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: 6020, 6030,
6031, 6822
Min:
1.000
Max:
10000.000
Factory setting:
1.000
Description:
Sets the ratio between the total moment of inertia/mass (load + motor) and the intrinsic motor moment of inertia/mass
(no load).
Dependency:
This means that together with p0341, the rated starting (accelerating time) of the motor is calculated for a vector drive.
See also: p0341, r0345
Note
The product of p0341 * p0342 is used when the speed controller (p0340 = 4) is calculated automatically.
p0344[0...n]
Motor weight (for the thermal motor model) / Mot weight th mod
Access level: 3
Calculated: CALC_MOD_ALL Data type: FloatingPoint32
Can be changed: T
Scaling: -
Dynamic index: MDS, p0130
Unit group: 27_1
Unit selection: p0100
Function diagram: -
Min:
0.0 [kg]
Max:
50000.0 [kg]
Factory setting:
0.0 [kg]
Description:
Sets the motor weight.
Dependency:
IEC drives (p0100 = 0): unit kg
NEMA drives (p0100 = 1): unit lb
NOTICE
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected.
Information in p0300 should be carefully observed when removing write protection.
Note
The parameter influences the thermal 3 mass model of the induction motor.
The parameter is not used for synchronous motors (p0300 = 2xx).
r0345[0...n]
Nominal motor starting time / Mot t_start_rated
Access level: 3
Calculated: -
Data type: FloatingPoint32
Can be changed: -
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
- [s]
Max:
- [s]
Factory setting:
- [s]
Description:
Displays the rated motor starting time.
This time corresponds to the time from standstill up to reaching the motor rated speed and the acceleration with motor
rated torque (r0333).
Dependency:
See also: r0313, r0333, p0341, p0342
p0346[0...n]
Motor excitation build-up time / Mot t_excitation
Access level: 3
Calculated: CALC_MOD_REG Data type: FloatingPoint32
Can be changed: T, U
Scaling: -
Dynamic index: MDS, p0130
Unit group: -
Unit selection: -
Function diagram: -
Min:
0.000 [s]
Max:
20.000 [s]
Factory setting:
0.000 [s]
Parameters
7.3 Parameters
SINAMICS G120XA converter
400
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB