Property
Explanation
Surrounding air temperature dur‐
ing storage
● FSA ... FSG: -40 °C to +70 °C
● FSH/FSJ: -25 °C to +55 °C
Shock and vibration
● FSA ... FSG
– Transport in the transport packaging according to Class 2M3 according to EN
61800-5-1 and EN 60068-2-6
– Vibration in operation according to Class 3M1 according to EN 60721-3-3: 1995
● FSH/FSJ
– Vibration during operation: Fc test according to EN 60068-2-6 0.075 mm for 10 ...
58 Hz 9.81 m/s² (1 x g) at > 58 ... 200 Hz
– Shock during operation: Test according to EN 60068- 2-27 100 m/s² (10 x g)/11 ms
– Vibration during product packaging: Fc test according to EN 60068-2-64 30 min/
axis, 3 axes 10 ... 200 Hz ASD 1.0 (m
2
/s
3
)
– Shock during product packaging: Fc test according to EN 60068-2-27 10 x g/11 ms
Protection against chemical sub‐
stances
Protected according to 3C2 to EN 60721‑3‑3
Pollution
Suitable for environments with degree of pollution 2 according to EN 61800-5-1
Sound pressure level L
PA
(1 m)
≤ 76 dB (A)
1)
Cooling method
Air forced cooling
Cooling air
Clean and dry air
1)
Maximum sound pressure level, ascertained in the IP20 cabinet
Technical data
11.3 General converter technical data
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB