MX-3114N DISASSEMBLY AND ASSEMBLY 10 – 33
When the OPC drum is removed, perform the following procedures.
1)
After removing the OPC drum, apply stearic acid powder
(UKOG-0312FCZZ) to the whole surface of the OPC drum.
2)
After attaching the OPC drum to the OPC drum frame, use the
black protect sheet or copy paper, and manually rotate the
OPC drum two turns in the forward direction to remove stearic
acid powder applied to the OPC drum surface.
• Do not touch the OPC drum surface except for the both ends
(5mm) of the OPC drum.
• Any section of the OPC drum may be touched from above
the black protect sheet, but do not touch too strongly.
(2) MC cleaning rod
a. Charger cleaner
1)
Open the front cabinet, and remove the MC cleaning rod.
2)
Remove the charger cleaner at the lead edge of the MC clean-
ing rod, and attach a new charger cleaner.
No.
Name
1
Charger cleaner
1
1
2