MX-3114N SIMULATION 6 – 97
Input value
56
56-1
Purpose
Backup
Function (Purpose)
Used to transport data between HDD - MFP
PWB SRAM/EEPROM. (Used to repair the
PWB.)
Section
Operation/Procedure
1)
Select a target content of data transfer.
2)
Press [EXECUTE] key and press [YES] key.
Data transfer of the item selected in procedure 1) is executed.
When the operation is completed normally, "COMPLETE" is
displayed. In case of an abnormal end, "ERROR" is displayed.
56-2
Purpose
Data backup
Function (Purpose)
Used to backup the data in the EEPROM.
SD Card, and HDD (including user authen-
tication data and address data) to the USB
memory. (Corresponding to the device
cloning and the storage backup.)
Section
Operation/Procedure
1)
Insert the USB memory into the main unit.
2)
Select a target transfer item with the touch panel.
<IMPORT>
From USB MEMORY DEVICE To EEPROM, SD Card HDD
<EXPORT>
From EEPROM, SD Card, HDD To USB MEMORY
3)
Press [EXECUTE] key, and press [YES] key.
Data transfer selected in the procedure 2) is performed
When the operation is completed normally, "COMPLETE" is
displayed. In case of an abnormal end, "ERROR" is displayed.
(Machine with the DSK installed)
1)
Insert the USB memory into the main unit.
2)
Select a target transfer item with the touch panel.
<IMPORT>
From USB MEMORY DEVICE to EEPROM, SD Card HDD
<EXPORT>
From EEPROM, SD Card, HDD to USB MEMORY DEVICE
3)
Enter the password with 10-key.
4)
Press [SET] key.
5)
Press [EXECUTE] key, and press [YES] key.
Data transfer selected in the procedure 2) is performed.
When the operation is completed normally, "COMPLETE" is
displayed. In case of an abnormal end, "ERROR" is displayed.
<Data list outside the backup targets>
(EEPROM/SD Card)
(HDD)
H
TYPE
PATTERN
1
Print
com-
posing
method
Edging
type
0
1
PATTERN
2
OR
process
type
1
PATTERN
3
No-
delete-
compo-
sition type
2
Blank
A
B
C
E
F
G
Input value
32
65
66
67
69
70
71
H
I
J
K
L
M
N
Input value
72
73
74
75
76
77
78
O
P
Q
R
T
U
V
Input value
79
80
81
82
84
85
86
W
X
Y
Z
0
1
2
Input value
87
88
89
90
48
49
50
3
5
6
7
8
9
Input value
51
53
54
55
56
57
EEPROM
HDD
Transfer from EEPROM to HDD
HDD
EEPROM
Transfer from HDD to EEPROM
Item/Display
Content
Setting
range
Default
value
PWB Type
Content
NOTE
Controller
Machine serial No.
Product key information
Various counter
Copy counter/FAX
send counter etc.
Trouble history
PCU
Machine serial No.
Various counter
Maintenance counter
Machine adjustment execute
history
Trouble history
SCU
Various counter
Maintenance counter
Trouble history
Classifi-
cation
Content
NOTE
Japanese
FEP
User dictionary
Job end list
Job end list display data
(The image send series include
the preserved job list.)
Log
Job log
Read from WEB is
enable.
New N/A
• Print history information
• JAM history information
• Trouble history information
• Same position continuous jam
count value
• Charging information
• Life information
Operation
manual