MX-3114N SIMULATION 6 – 91
Error displays in case of abnormal end
50-24
Purpose
(This simulation is normally not used in the
market.)
Function (Purpose)
Used to display the detail data of SIM 44-2,
50-20 and 22.
Section
Operation/Procedure
This simulation is mainly used by the technical division, and is not
necessary for the market.
50-27
Purpose
Adjustment
Function (Purpose)
Used to perform the image loss adjustment
of scanned images in the FAX or image
send mode.
Section
Operation/Procedure
1)
Select a target adjustment mode with [FAX] or [SCANNER]
key.
2)
Select an adjustment target item with scroll key on the touch
panel.
3)
Enter the set value with 10-key.
4)
Press [OK] key. (The set value is saved.)
[RSPF]
Error code
Error display
Error content
Description
Forcible end error
-
SUSPENDED
Door open end
Door open during operation
-
SUSPENDED
CA end
CA button pressed during operation
-
-
OFF end
Unconfirmed operation during operation (Power OFF)
Basic error
1
TONNER EMPTY
Toner Empty
BK or ALL Color toner EMPTY detection
2
BEFOR BEHAVIOR
Other condition
Other condition
4
SENSOR CALIBLATION F
Calibration error F
The target is not reached by 3 times of retry of F or R
5
SENSOR CALIBLATION R
Calibration error R
6
SENSOR CALIBLATION FR
Calibration error FR
7
TIME OVER
Time error
No data are obtained for 90sec from data acquisition
8
PROCESS CONTROL
Process control error
Process control error detection
Sub scanning
adjustment error
10 - 47
SUB XXX XXXX XXX
Main scanning
adjustment error
50 - 88
MAIN XXX XXXX XXX
Others
99
OTHER 99
Other errors
Other errors
Item/Display
Content
Setting range
Default value
FAX send
A
Image loss
amount setting OC
LEAD_EDGE (OC)
OC lead edge image loss amount setting
0 - 100
30 (3mm)
B
FRONT_REAR (OC)
OC side image loss amount setting
0 - 100
20 (2mm)
C
TRAIL_EDGE (OC)
OC rear edge image loss amount setting
0 - 100
20 (2mm)
D
Image loss
amount setting
SPF SIDE1
LEAD_EDGE (SPF_SIDE1)
Front surface lead edge image loss
amount setting
0 - 100
20 (2mm)
E
FRONT_REAR (SPF_SIDE1)
Front surface side image loss amount
setting
0 - 100
20 (2mm)
F
TRAIL_EDGE (SPF_SIDE1)
Front surface rear edge image loss
amount setting
0 - 100
30 (3mm)
G
Image loss
amount setting
SPF SIDE2
LEAD_EDGE (SPF_SIDE2)
Back surface lead edge image loss
amount setting
0 - 100
20 (2mm)
H
FRONT_REAR (SPF_SIDE2)
Back surface side image loss amount
setting
0 - 100
20 (2mm)
I
TRAIL_EDGE (SPF_SIDE2)
Back surface rear edge image loss
amount setting
0 - 100
30 (3mm)