MX-3114N SIMULATION 6 – 45
43-2
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature in each
mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Item/Display
Content
Setting
value
Default value (SW-A)
Default value (SW-B)
Group
A
Group
B
Group
C
Group
A
Group
B
Group
C
A
HL_UM READY
Ready stanby TH_UM set value
70 - 230
115
130
130
140
140
145
B
HL_LM READY
Ready stanby TH_LM set value
30 - 200
90
105
105
100
115
115
C
HL_US READY
Ready stanby TH_US set value
70 - 230
145
150
155
155
160
165
D
HL_UM PLAIN PAPER BW
Monochrome plain paper TH_UM set value
70 - 230
145
145
155
155
155
165
E
HL_LM PLAIN PAPER BW
Monochrome plain paper TH_LM set value
30 - 200
110
115
115
115
125
125
F
HL_US PLAIN PAPER BW
Monochrome plain paper TH_US set value
70 - 230
145
150
155
150
155
160
G
HL_UM PLAIN PAPER CL
Color plain paper TH_UM set value
70 - 230
145
150
155
160
160
165
H
HL_LM PLAIN PAPER CL
Color plain paper TH_LM set value
30 - 200
110
115
115
115
125
125
I
HL_US PLAIN PAPER CL
Color plain paper TH_US set value
70 - 230
145
150
155
155
160
165
J
WARMUP FUMON HL_US
T
Fusing motor pre-rotation start TH_US set
value
30 - 200
50
50
50
50
50
50
K
WARMUP FUMOFF
Fusing motor previous rotation complete time
0 - 255
20
20
20
20
20
20
L
WARMUP END TIME
Warm up complete time
1 - 255
14
14
14
14
14
14
M
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 230
180
180
180
180
180
180
N
HL_LM HEAVY PAPER
Heavy paper TH_LM set value
30 - 200
120
120
120
120
120
120
O
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 230
150
150
150
150
150
150
P
HL_UM OHP PAPER
OHP TH_UM set value
70 - 230
195
195
195
195
195
195
Q
HL_LM OHP PAPER
OHP TH_LM set value
30 - 200
125
125
125
125
125
125
R
HL_US OHP PAPER
OHP TH_US set value
70 - 230
175
175
175
175
175
175
S
HL_UM ENV PAPER
Envelope TH_UM set value
70 - 230
195
195
195
195
195
195
T
HL_LM ENV PAPER
Envelope TH_LM set value
30 - 200
125
125
125
125
125
125
U
HL_US ENV PAPER
Envelope TH_US set value
70 - 230
175
175
175
175
175
175
V
HL_UM GLOSS PAPER
Gloss paper TH_UM set value
70 - 230
200
200
200
200
200
200
W
HL_LM GLOSS PAPER
Gloss paper TH_LM set value
30 - 200
120
120
120
120
120
120
X
HL_US GLOSS PAPER
Gloss paper TH_US set value
70 - 230
180
180
180
180
180
180
Y
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
110
115
120
110
115
120
Z
HL_US E-STAR
Preheating TH_US set value
30 - 200
130
130
130
130
130
130
AA
HL_UM PRE-JOB
Preheat mode restore complete temperature
30 - 200
140
145
150
155
155
160
AB
HL_LM E-STAR
Preheating TH_LM set value
30 - 200
70
90
90
70
90
90
AC
HL_UM HEAVY2 PAPER
Heavy paper 2 TH_UM set value
70 - 230
190
190
190
190
190
190
AD
HL_LM HEAVY2 PAPER
Heavy paper 2 TH_LM set value
30 - 200
120
120
120
120
120
120
AE
HL_US HEAVY2 PAPER
Heavy paper 2 TH_US set value
70 - 230
160
160
160
160
160
160
AF
HL_UM HEAVY3 PAPER
Heavy paper 3 TH_UM set value
70 - 230
185
185
185
185
185
185
AG
HL_LM HEAVY3 PAPER
Heavy paper 3 TH_LM set value
30 - 200
120
120
120
120
120
120
AH
HL_US HEAVY3 PAPER
Heavy paper 3 TH_US set value
70 - 230
160
160
160
160
160
160
AI
HL_UM WARMUP_120L
TH_UM set value when warm up at 120
C or
below
70 - 230
155
160
165
160
165
170
AJ
HL_LM WARMUP_120L
TH_LM set value when warm up at 120
C or
below
30 - 200
50
50
50
50
50
50
AK
HL_US WARMUP_120L
TH_US set value when warm up at 120
C or
below
70 - 230
135
140
150
150
145
155
AL
LO_WARMUP_TIME
Item AI-AK applying time
(Timer from completion of ready)
0 - 255
0
0
0
0
0
0
AM
HL_UM WARMUP_120H
TH_UM set value when warm up at 120
C or
above
70 - 230
155
160
165
160
165
170
AN
HL_LM WARMUP_120H
TH_LM set value when warm up at 120
C or
above
30 - 200
50
50
50
50
50
50
AO
HL_US WARMUP_120H
TH_US set value when warm up at 120
C or
above
70 - 230
135
140
150
150
145
155
AP
HI_WARMUP_TIME
Item AM-AO applying time
(Timer from completion of ready)
0 - 255
0
0
0
0
0
0
AQ
HI_WU_FM_ON_TMP
FM prior rotation start TH_US when warm up
at alpha
C or above
30 - 200
50
50
50
50
50
50
AR
HI_WU_END_TIME
Warm up completion time when warm up at
alpha
C or above
0 - 255
14
14
14
14
14
14
AS
HI_WU_JOB_SET_TMP
Job enable TH_UM temperature when warm
up at alpha
C or above
70 - 230
155
160
165
160
165
170