MX-3114N SIMULATION 6 – 84
48-5
Purpose
Adjustment
Function (Purpose)
Used to correction the scan image magnifi-
cation ratio (in the sub scanning direction).
Section
Scanner section
Operation/Procedure
1)
Select a target adjustment item with scroll key on the touch
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value is saved.
When the image magnification ratio in the sub scanning direction is
adjusted with SIM48-1, and a different magnification ratio is speci-
fied, and the image magnification ratio is not satisfactory, perform
this adjustment.
When there is an error in the image magnification ratio in reduction,
change the adjustment value in the high speed mode. When there
is an error in the image magnification ratio in enlargement, change
the adjustment value in the low speed mode.
48-6
Purpose
Adjustment
Function (Purpose)
Used to adjust the rotation speed of each
motor.
Section
Operation/Procedure
1)
Select an adjustment target mode with [COLOR] [MONO]
[HEAVY] keys on the touch panel.
2)
Select a target adjustment item with scroll key on the touch
panel.
3)
Enter the set value with 10-key.
4)
Press [OK] key.
The set value is saved.
When the adjustment value is increased, the speed is increased,
and vice versa. A change of 1 in the adjustment value corresponds
to a change of about 0.1% in the speed.
* Common items for color, monochrome, and heavy paper
** Common items for color and monochrome
The greater the correction value is, the higher the speed is, and
vice versa. Change by ±1 corresponds to 0.1%.
49
49-1
Purpose
Function (Purpose)
Used to perform the firmware update.
Section
Operation/Procedure
1)
Save the firmware to the USB memory.
2)
Insert the USB memory into the main unit. (Use USB I/F of the
operation panel section.)
3)
Select a target firmware file for update with the touch panel.
4)
Select a target firmware.
Press [ALL] key to select all the Firmware collectively.
5)
Press [EXECUTE] key.
6)
Press [YES] key.
The selected firmware is updated. When the operation is nor-
mally completed, "COMPLETE" is displayed. When terminated
abnormally, "ERROR" is displayed.
Item/Display
Content
Setting
range
Default
value
A
MR (HI)
Scanner motor (High speed)
1 - 99
50
B
MR(MID)
Scanner motor (Reference speed)
1 - 99
50
C
MR(LO)
Scanner motor (Low speed)
1 - 99
50
D
SPF(HI)
Document feed (SPF) motor
(High speed)
1 - 99
50
E
SPF(MID)
Document feed (SPF) motor
(Reference speed)
1 - 99
50
Mode
Select
Item/Display
Content
Setting
range
Default
value
COLOR
A
RRM
Registration motor
correction value
1 - 99
51
MONO
HEAVY
COLOR
B
BTM
Belt motor correction
value
1 - 99
47
MONO
HEAVY
COLOR
C
DVM_K
Developing K motor
correction value
1 - 99
45
MONO
HEAVY
COLOR**
D
FSM
Fusing motor
correction value
1 - 99
44
HEAVY
41
COLOR
E
DVM_CL
Developing CL motor
correction value
1 - 99
45
HEAVY
COLOR*
F
PFM
Paper transport motor
correction value
1 - 99
48
COLOR*
G
POM
Paper exit motor
correction value
1 - 99
50
HEAVY
H
FUSER
SETTING
Fusing speed select
timing
1 - 99
60
HEAVY
I
RRM
START
Registration motor
speed increasing start
timing
0 - 255
109
HEAVY
J
RRM
END
Registration motor
speed increasing end
timing
0 - 255
210
Item/Display
Content
Error display in
case of abnormality
ICU (MAIN)
ICU Main section
ICUM
ICU (BOOTM)
ICU Boot section main
ICUBM
ICU (BOOTCN)
ICU Boot section CN
ICUCN
ICU (SUB)
ICU Sub section (ARM9)
ICUS
LANGUAGE
Language support data
program
LANG
GRAPHIC
Graphic data for L-LCD
GRAPH
SLIST
SLIST data for L-LCD
SLIST
PCL (BOOT)
PCL Boot section
PCLB
PCL (MAIN)
PCL Main section
PCLM
PCL (CONFIG)
PCL Configuration data
PCLC
PCL (PROFILE)
PCL Color profile
PCLP
PCU (BOOT)
PCU Boot section
PCUB
PCU (MAIN)
PCU Main section
PCUM
DESK (BOOT)
Desk unit boot section
DESKB
DESK (MAIN)
Desk unit main section
DESKM
FIN (BOOT)
Inner finisher boot section
FINB
FIN (MAIN)
Inner finisher main section
FINM
SCU (BOOT)
SCU Boot section
SCUB
SCU (MAIN)
SCU Main section
SCUM
FAX (BOOT)
FAX1 Boot section
FAXB
FAX (MAIN)
FAX1 Main section
FAXM
ANIMATION
Animation data
ANIME
WEB HELP
WEB help
WEBHP
EOSA
Embedded OSA
EOSA
Mode
Select
Item/Display
Content
Setting
range
Default
value