MX-3114N SIMULATION 6 – 54
44
44-1
Purpose
Setting
Function (Purpose)
Used to set each correction operation func-
tion in the image forming (process) section.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1)
Select an item to be set with the touch panel.
(The selected item is highlighted.)
2)
Press [EXECUTE] key. (The set value is saved.)
Set the items to the default values unless a change is specially
required.
44-2
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the sensitivity of the image
density sensor (registration sensor).
Section
Process
Operation/Procedure
When [EXECUTE] key is pressed, the adjustment is executed auto-
matically.
After completion of the adjustment, the adjustment result is dis-
played.
If the adjustment is not executed normally, "ERROR" is displayed.
Item/
Display
Content
Setting
range
Default
value
NOTE
HV
Normal operation high
density process control
Enable/Disable setting
Normal
(Disable:
1: NO)
Reverse
(Enable:
0: YES)
Enable
HT
Normal operation
halftone process control
Enable/Disable setting
Enable
TC
Transfer output
correction Enable/
Disable setting
Enable
MD VG
Membrane decrease
grid voltage correction
Enable/Disable setting
Enable
MD LD
Membrane laser power
voltage correction
Enable/Disable setting
Disable
MD EV
Membrane decrease
environment grid
voltage correction
Enable/Disable setting
Enable
MD DL
Membrane decrease
discharge light quantity
correction Enable/
Disable setting
Enable
MD DL EV
Membrane decrease
environment discharge
light quantity correction
Enable/Disable setting
Disable
TN_PIX_
SUP
Setting of Enable/
Disable of toner supply
control for the yield
count
Enable
TN_FB
Setting of Enable/
Disable of the toner
density correction for
the process control
result
Enable
TN_INT
Setting of Enable/
Disable of toner
compulsory supply
correction for the
development traveling
distance
Enable
TN_RECV
Setting of Enable/
Disable of the toner
density recovery
operation
Enable
TN_ADJ
Setting of Enable/
Disable of the toner
sensor control voltage
adjustment in the
process control
Enable
TN_EMP
Setting of Enable/
Disable of the toner
falling distance
detection control
Normal
(Disable:
1: NO)
Reverse
(Enable:
0: YES)
Enable
TN_EMP_
INT
Setting of Enable/
Disable of the toner
falling distance
detection control of job
interruption
Enable
TN_EMP_
NEW
Setting of Enable/
Disable of the new
toner cartridge falling
distance detection
control
Enable
TN_PIX_
TBL
Setting of Enable/
Disable of execution of
revision of the yield
count conversion table
for the toner supply
control in the halftone
process control
Enable
AR_AUTO
Auto registration
adjustment Enable/
Disable setting
Enable
AR_ERROR
Auto registration
adjustment execution
error check Enable/
Disable setting
Enable
DM_PHASE
Drum phase fitting
Enable/Disable setting
Enable
PRT_HT
Halftone process
control printer
correction feedback
Enable/Disable setting
Enable
PTC_ENV
PTC environment
correction Enable/
Disable setting
Enable
Enable:
Correc-
tion ON
Classifi-
cation
Item/Display
Content
Setting
range
Default
value
PROCON
A
PCS_F_C
L_KA
Color image sensor
light emitting
quantity
adjustment value
1 - 255
500
B
PCS_F
LED ADJ
Image sensor light
emitting quantity
adjustment value F
1 - 255
21
C
PCS_R
LED ADJ
Image sensor light
emitting quantity
adjustment value R
0 - 255
21
D
PCS_F_C
L_DARK
Dark voltage of
color image sensor
0 - 255
0
E
PCS_F
DARK
Dark voltage of
image sensor F
0 - 255
0
F
PCS_R
DARK
Dark voltage of
image sensor R
0 - 255
0
Item/
Display
Content
Setting
range
Default
value
NOTE