MX-3114N SIMULATION 6 – 104
62-14
Purpose
Data clear
Function (Purpose)
Used to delete the document filing manage-
ment data.
Section
HDD
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The document filing management data are cleared.
At the same time, the job log data are also cleared.
This simulation is executed in the following trouble cases.
* The document filing function does not work normally.
* The job log is not recorded normally.
This simulation may not function with some firmware versions.
In such a case, the firmware must be upgraded to the latest ver-
sion.
63
63-1
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to display the shading correction
result.
Section
Scanner
Operation/Procedure
1)
Select a target color to display with [R] [G] [B] on the touch
panel.
[RSPF]
63-2
Purpose
Adjustment
Function (Purpose)
Used to perform shading.
Section
Operation/Procedure
1)
(When RSPF model)
Press [EXECUTE] key.
Used to perform shading.
When the operation is completed, [EXECUTE] key returns to the
normal display.
63-3
Purpose
Adjustment
Function (Purpose)
Used to perform scanner (CCD) color bal-
ance and gamma auto adjustment.
Section
Scanner
Operation/Procedure
1)
Place the SIT chart (UKOG-0280FCZZ or UKOG-0280FCZ1)
on the reference position of the left rear frame side of the doc-
ument table.
2)
Press [EXECUTE] key.
The scanner (CCD) color balance automatic adjustment is per-
formed.
When the operation is completed, [EXECUTE] key returns to the
normal display.
After completion of the operation, press [RESULT] key, and the
adjustment data are displayed. At that time, the target color of data
display can be selected with [R] [G] [B] key.
Display item
Description
Remarks
ANALOG
GAIN ODD
Analog gain adjustment
value (odd number)
ANALOG
GAIN EVEN
Analog gain adjustment
value (even number)
DIGITAL GAIN
ODD
Digital gain adjustment
value (odd number)
DIGITAL GAIN
EVEN
Digital gain adjustment
value (even number)
SMP AVE
ODD
Reference plate
sampling average value
(ODD)
SMP AVE
EVEN
Reference plate
sampling average value
(EVEN)
TARGET
VALUE
Target value
BLACK LEVEL
Black output level
ERROR CODE
Error code (0, 1 - 14)
0:
No error
1:
Loop number over
2:
The target value is
under the speci-
fied value
3:
The gain set value is
negative.
4:
END is not asserted.
(Gain adjustment)
5:
Reserve
6:
Underflow
7:
Black shading error
8:
Other error
9:
END is not asserted.
(White shading)
10:
END is not asserted.
(Black shading)
ERROR
CODE
Error code (0, 1 - 14)
11:
END is not asserted.
(Light quantity
correction)
12:
END is not asserted.
13:
Register check error
(White booting/Before
gain)
14:
Register check error
(Before light quantity
correction)
RSPF BACK
WHITE
LEVEL 1ST
First scan RSPF back
surface white reference
level
RSPF BACK
WHITE
LEVEL 2ND
Second scan RSPF back
surface white reference
level
Display item
Description
Remarks