MX-3114N SIMULATION 6 – 49
43-21
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-2) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
Correction value: -49 - +49, Input value: Actually inputted value (1 -
99)
* Item WARMUP END TIME HH: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
C change
Code descriptions
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Default value
Group
A
Group
B
Group
C
A
HL_UM READY HH
Correction value for TH_UM set value in Ready standby under HH environment
1 - 99
40
45
50
B
HL_LM READY HH
Correction value for TH_LM set value in Ready standby under HH environment
1 - 99
40
45
50
C
HL_US READY HH
Correction value for TH_US set value in Ready standby under HH environment
1 - 99
40
45
50
D
HL_UM PLAIN BW HH
Correction value for Black-White plain paper TH_UM set value under HH environment
1 - 99
40
45
50
E
HL_LM PLAIN BW HH
Correction value for Black-White plain paper TH_LM set value under HH environment
1 - 99
40
45
50
F
HL_US PLAIN BW HH
Correction value for Black-White plain paper TH_US set value under HH environment
1 - 99
40
45
50
G
HL_UM PLAIN CL HH
Correction value for Color plain paper TH_UM set value under HH environment
1 - 99
40
45
50
H
HL_LM PLAIN CL HH
Correction value for Color plain paper TH_LM set value under HH environment
1 - 99
40
45
50
I
HL_US PLAIN CL HH
Correction value for Color plain paper TH_US set value under HH environment
1 - 99
40
45
50
J
WARMUP FUMON HL_US T
HH
Correction value for fusing motor pre-rotation start TH_US set value under HH
environment
1 - 99
50
50
50
K
WARMUP FUMOFF HH
Fusing motor prior rotation completion time under HH environment
1 - 99
50
50
50
L
WARMUP END TIME HH
Correction value for warm-up complete time under HH environment
1 - 99
50
50
50
M
HL_UM HEAVY HH
Correction value for heavy paper TH_UM set value under HH environment
1 - 99
50
50
50
N
HL_LM HEAVY HH
Correction value for heavy paper TH_LM set value under HH environment
1 - 99
50
50
50
O
HL_US HEAVY HH
Correction value for heavy paper TH_US set value under HH environment
1 - 99
50
50
50
P
HL_UM OHP HH
Correction value for OHP TH_UM set value under HH environment
1 - 99
50
50
50
Q
HL_LM OHP HH
Correction value for OHP TH_LM set value under HH environment
1 - 99
50
50
50
R
HL_US OHP HH
Correction value for OHP TH_US set value under HH environment
1 - 99
50
50
50
S
HL_UM ENVELOPE HH
Correction value for envelope TH_UM set value under HH environment
1 - 99
50
50
50
T
HL_LM ENVELOPE HH
Correction value for envelope TH_LM set value under HH environment
1 - 99
50
50
50
U
HL_US ENVELOPE HH
Correction value for envelope TH_US set value under HH environment
1 - 99
50
50
50
V
HL_UM GLOSS HH
Correction value for glossy paper TH_UM set value under HH environment
1 - 99
50
50
50
W
HL_LM GLOSS HH
Correction value for glossy paper TH_LM set value under HH environment
1 - 99
50
50
50
X
HL_US GLOSS HH
Correction value for glossy paper TH_US set value under HH environment
1 - 99
50
50
50
Y
HL_UM E-STAR HH
Correction value for preheating TH_UM set value under HH environment
1 - 99
40
45
50
Z
HL_US E-STAR HH
Correction value for preheating TH_US set value under HH environment
1 - 99
40
45
50
A
A
HL_UM PRE-JOB HH
Correction value for the set value of TH_UM when restoring from preheating under HH
environment
1 - 99
40
45
50
A
B
HL_LM E-STAR HH
Correction value for preheating TH_LM set value under HH environment
1 - 99
40
45
50
A
C
LO_WARMUP_TIME_HH
Correction value for AF-AH applying time (timer from Ready complete) under HH
environment
1 - 99
50
50
50
A
D
HI_WARMUP_TIME HH
Correction value for AJ-AL applying time (timer from Ready complete) under HH
environmentHH
1 - 99
50
50
50
A
E
HI_WU_FM_ON_TMP_HH
Correction value for FM prior rotation start TH_US in Warm-Up at alpha
C or above
under HH environment
1 - 99
50
50
50
A
F
HI_WU_END_TIME_HH
Correction value for Warm-Up completion time in Warm-Up at alpha
C or above under
HH environment
1 - 99
50
50
50
A
G
HI_WU_JOB_SET_TMP_H
H
Correction value for Job Enable TH_UM temperature in Warm-Up at alpha ?C or
above under HH environment
1 - 99
40
45
50
A
H
HI_WARMUP_BORDER_H
H
Correction value for the threshold value alpha applying SIM43-1-AN - AP under HH
environment
1 - 99
50
50
50
AI
LO_WU_JOB_SET_TMP_H
H
Correction value for Job Enable TH_UM temperature in Warm-Up at alpha ?C or
below under HH environment
1 - 99
40
45
50
AJ
JOBEND_FUMON_TIME
HH
Correction value for the after rotation time when completing a job under HH
environment
1 - 99
50
50
50
A
K
LO_WU_JOB_SET_TMP_B
W HH
Correction value (BW) for Job enable TH_UM temperature when Warm-Up at alpha
C
or above under HH environment
1 - 99
40
45
50
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)