MX-3114N SIMULATION 6 – 60
44-26
Purpose
Adjustment/Setup
Function (Purpose)
Used to execute the halftone process con-
trol compulsory.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
The halftone process control is performed and the operation data
are displayed.
44-27
Purpose
Data clear
Function (Purpose)
Used to clear the correction data of the half-
tone process control.
Section
Process
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The correction data of the halftone process control are cleared.
B
LOW FIELD
UPPER LIMIT
Low density
approximate
expression data upper
limit value
0 - 255
60
60
C
MID FIELD
LOWER LIMIT
Medium density
approximate
expression data lower
limit value
0 - 255
90
90
D
MID FIELD
UPPER LIMIT
Medium density
approximate
expression data upper
limit value
0 - 255
6
2
E
HIGHLIGHT
POINT
Reference point of the
highlight correction
amount
1 - 8
7
7
F
HIGHTLIGHT
VALUE LIMIT
Highlight correction
amount limit value
0 - 128
20
20
G
MAX VALUE
LIMIT
Maximum density value
correction limit value
0 - 128
20
20
COMPLETE
Normal complete
ERROR COLOR SENSOR
ADJUSTMENT
Color image density sensor sensitivity
adjustment error
ERROR BLACK SENSOR
ADJUSTMENT
Black image density sensor sensitivity
adjustment error
[YMCK]
High density process control error [YMCK]
error
OTHER
Other errors
Item/Display
Content
Setting
range
Default
value
K
CMY