MX-3114N SIMULATION 6 – 59
However, idle rotation is performed in a certain interval while in shut
off. This must be fully explained to the user.
44-21
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the halftone process control tar-
get.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
The halftone process control target is set and the operation data
are displayed.
44-22
Purpose
Operation data display
Function (Purpose)
Used to display the toner patch density
level in the halftone process control opera-
tion.
Section
Process
Operation/Procedure
1)
Select the display mode with [1ST STEP],[2ND STEP] key.
The toner patch density level made in the halftone process
control operation is displayed.
44-24
Purpose
Operation data display
Function (Purpose)
Used to display the correction target and
the correction level in the halftone process
control operation.
Section
Process
Operation/Procedure
1)
Select the display category with [NEXT] key.
2)
Select a target adjustment color with [K] [C] [M] [Y] key.
44-25
Purpose
Setting
Function (Purpose)
Used to set the calculating conditions of the
correction value for the halftone process
control.
Section
Process
Operation/Procedure
1)
Select a target adjustment color with [K] [C] [M] [Y] key.
2)
Select a target adjustment density level with scroll key on the
touch panel.
3)
Enter the set value with 10-key.
4)
Press [OK] key.
Set the items to the default values unless a change is specially
required.
Display
Content
COMPLETE
Normal complete
ERROR COLOR SENSOR
ADJUSTMENT
Color image density sensor
sensitivity adjustment error
ERROR BLACK SENSOR
ADJUSTMENT
Black image density sensor
sensitivity adjustment error
[YMCK]
High density process control error
[YMCK]
OTHER
Other errors
Item/Display
Content
ID_n
Patch data display
PTK/PTC/PTM/PTY : n=1 - 16
BASE1
Belt substrate data (START)
BASE5
Belt substrate data (LAST)
Category
Item/Display
Content
Coefficient
[EX-LOW]
Coefficient of the
approximation formula of the
minimum density
[LOW]
Coefficient of the
approximation formula of the
low density
[CONNECT]
Coefficient of the
approximation formula of when
connecting the low density and
the medium density
[MID]
Coefficient of the
approximation formula of the
medium density
[HIGH]
Coefficient of the
approximation formula of the
high density
[CONNECT POINT]
Each density section
connection output ratio
Reference
value
[SENSOR_TARGET]
Halftone process control
reference value
Correction
value
[S_VALUE]
Halftone process control
correction value
For printer
[PRINTER_S_VALUE]
Printer halftone process control
correction value
[PRINTER_BASE_
DITHER_VALUE]
Printer halftone process control
reference dither value
[PRINTER_AUTO_
HT_VALUE]
Printer auto density adjustment
correction value
Previous
correction
value
[BEFORE S_VALUE]
Previous halftone process
control value
Item/Display
Content
Setting
range
Default
value
K
CMY
A
LOW FIELD
LOWER LIMIT
Low density
approximate
expression data lower
limit value
0 - 255
98
98