MX-3114N SIMULATION 6 – 62
Setting of the
execution
conditions of
the process
control
L
LO-COV
Setting of the execution judgment of the
process control in continuous printing of
low print ratio images
Enable
0 - 1
0
0
Inhibit
1
M
TonerCA-END
Setting of the process control interval
reduction when the toner cartridge
remaining quantity is 25% or less (If this is
set to Enable, item M RATIO is changed.)
Enable
0 - 1
0
1
Inhibit
1
N
AVERAGE-PAGE
Setting of the number of pages of item HI-
COV set value 2
1: 10 pages - 5: 50 pages
1 step corresponds to 10
pages.
1 - 5
1
3
5
O
LIMIT PAGE
Setting of the number of connected jobs of
the process control and of the limit number
of the process control
1: 10 pages - 10: 100
pages
1 step corresponds to 10
pages.
1 -10
1
10
A number of reservation jobs are
connected. When the number of jobs
exceeds the specified number of pages
(the set value of this setting), the process
control is performed. / The process control
is performed by AND conditions of item
REV condition and the specified number of
pages (the set value of this setting).
10
P
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value
The set value of 100 corresponds to K print of A4 at the print ratio of 5%.
1 - 999
10
Q
PIX_RATIO_CL
Magnification ratio setting (%) of the color (CMY) toner count specified
value
The set value of 100 corresponds to K print of A4 at the print ratio of 5%.
1 - 999
10
R
INTERVAL TIME
Setting of the leaving time when turning ON the power (including the
sleep recovery time) (h: hour)
1 - 255
3
S
HUM HOUR
Interval setting of the temperature and humidity monitoring time of
"HUM" (unit: 10 minutes)
1 - 24
2
T
HUM_DIF
The specified value of the area difference in humidity between the level
at execution of the previous control and the current humidity (Applied to
item HUM)
1 - 9
2
U
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK OPC
drum traveling distance of "REV2_BK"
1 - 999 (Entry of 20
corresponds to
100,000mm.)
15
V
M_RATIO
Magnification ratio setting (%) of the M OPC drum traveling distance of
"REV2_CL"
1 - 999 (Entry of 20
corresponds to
100,000mm.)
15
W
COLOR BORDER
Judgment criteria whether the BK high
density process control is individually
performed or not (Setting of the ratio of the
M OPC drum rotation distance for the K
OPC drum rotation distance (%))
0: The BK process control
is executed regardless of
the M OPC drum traveling
distance.
0 - 999
20
1 - 999: 1 - 999(%)
X
BK ONLY
Setting of the frequency of execution of the
4-color high density process control when
only monochrome output is continued (The
result of this setting is applied only when
the M OPC drum rotation distance is
smaller than the set value of COLOR
BORDER.)
Frequency of once for 5
times
0 - 6
0
5
Frequency of once for 1 - 5
times
1 - 5
The 4-color high density
process control is always
performed.
6
Y
HT_DIF
HT process control execution judgment developing bias variation value
1 - 255
40
Setting of the
execution
condition of the
registration
adjustment
Z
RG_ON_
SYNC
CL
Setting of execution of the registration adjustment when executing the
process control when turning ON the power
When the color
process control is
executed.
0
0
ALL
Executed
regardless of the
process control.
1
CL/BK
When the color
process control
and the K process
control are
executed.
2
AA
RG_TEMP_TIMER
Time interval from registration adjustment after turning ON the power to
the next execution.
0 - 240
(MINUTE)
0
AB
RG_PERM_TIMER
Setting of inhibit time of execution of the registration adjustment
0 - 15
(HOUR)
1
AC
RG_HOUR_TIMER
Setting of the interval time of execution of the registration adjustment
0 - 15
(Above)+(HOUR)
5
AD
RG_BW_SYNC
Setting of Enable/Disable of the
registration adjustment after a
monochrome job
Enable
0 - 1
0
1
Inhibit
1
Mode
Item/Display
Content
Setting range
Default
value