MX3114N TROUBLESHOOTING 7 – 31
(4)
Relation between the MFPC PWB LED status and
errors
When the machine cannot be booted, check the LED status of the
MFPC PWB to presume the error content and its cause.
<Process content and LED display>
*
: LED ON /
: LED OFF
<When an error occurs>
* In case of an error, the LED's flash as shown in the above table.
*
: LED ON /
: LED OFF
LED status
(Lighting)
Process operation content
Cause for halt during
operation
CPU initial setting
Reus ASIC trouble
Memory adjustment
Memory and its
peripheral circuit trouble
Memory check
Memory and its
peripheral circuit trouble
–
–
Program memory development
Memory-related trouble
Interruption-related initialization
Reus ASIC trouble
PCIe initialization
PCIe and its peripheral
circuit trouble (SoC, etc.)
Basic device initialization
Reus ASIC trouble
SD card initialization
SATA initialization
Reus ASIC trouble
SD card trouble
HDD trouble
OS initialization (1)
Reus ASIC trouble
Timer enabling
Reus ASIC trouble
Serial driver enabling
I2C driver enabling
Reus ASIC trouble
LCD initialization
Reus ASIC trouble
Image process IP initialization
Reus ASIC trouble
OS initialization (2)
Reus ASIC trouble
Main process
Reus ASIC trouble
LED status
(Flashing)
Error content
Cause
Nonsupport memory
Memory trouble
Nonsupport memory (access
speed)
Memory trouble
Nonsupport memory controller
Memory trouble
DDR-PHY setting error
Reus ASIC trouble
Interruption handler process
error
Reus ASIC trouble
Memory check error
Memory trouble
Memory combination error
Memory trouble
LED No
D25/D24/D23/D22