MX-3114N SIMULATION 6 – 16
8-2
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
* When the middle speed is adjusted, the
low speed are also adjusted simulta-
neously.
Section
Process (Charging)
Operation/Procedure
1)
Select a speed with [MIDDLE] and [LOW] keys on the touch
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the adjustment value with 10-key. (The value specified
on the label of the high voltage PWB must be entered.)
* When the
key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4)
Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the transport voltage and the control circuit.
Section
Process (Transport)
Operation/Procedure
1)
Select a target item to be adjusted with scroll keys.
2)
Enter the set value with 10-key.
Enter the default value specified on the following list.
3)
Press [EXECUTE] key.
The set value is saved and the voltage corresponding to the
set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display (Mode)
Content
Adjustment
range
Actual voltage
MIDDLE
A
MIDDLE SPEED GB_K
Main charger grid voltage (Middle speed mode)
K
150 - 850
–620V
5V
B
MIDDLE SPEED GB_C
Main charger grid voltage (Middle speed mode)
C
150 - 850
–620V
5V
C
MIDDLE SPEED GB_M
Main charger grid voltage (Middle speed mode)
M
150 - 850
–620V
5V
D
MIDDLE SPEED GB_Y
Main charger grid voltage (Middle speed mode)
Y
150 - 850
–620V
5V
LOW
A
LOW SPEED GB_K
Main charger grid voltage (Low speed mode)
K
150 - 850
–610V
5V
B
LOW SPEED GB_C
Main charger grid voltage (Low speed mode)
C
150 - 850
–590V
5V
C
LOW SPEED GB_M
Main charger grid voltage (Low speed mode)
M
150 - 850
–590V
5V
D
LOW SPEED GB_Y
Main charger grid voltage (Low speed mode)
Y
150 - 850
–590V
5V
Item/Display
Content
Setting
value
Default value
23cpm
26cpm/31cpm
A
TC1 LOW SPEED CL K
Primary transfer bias
adjustment value
Color
K
Low speed
51 - 255
80
80
B
TC1 MIDDLE SPEED CL K
Middle
speed
51 - 255
95
109
C
TC1 LOW SPEED CL C
C
Low speed
51 -255
80
80
D
TC1 MIDDLE SPEED CL C
Middle
speed
51 - 255
95
109
E
TC1 LOW SPEED CL M
M
Low speed
51 - 255
80
80
F
TC1 MIDDLE SPEED CL M
Middle
speed
51 - 255
95
109
G
TC1 LOW SPEED CL Y
Y
Low speed
51 - 255
80
80
H
TC1 MIDDLE SPEED CL Y
Middle
speed
51 - 255
95
109
I
TC1 LOW SPEED BW K
Black/
White
K
Low speed
51 - 255
80
80
J
TC1 MIDDLE SPEED BW K
Middle
speed
51 - 255
95
109
K
TC2 PLAIN CL SPX
Secondary transfer bias
adjustment value
Color
Plain
paper
Front
surface
51 - 255
96
103
L
TC2 PLAIN CL DPX
Back
surface
51 - 255
76
90
M
TC2 PLAIN BW SPX
Black/
White
Front
surface
51 - 255
96
103
N
TC2 PLAIN BW DPX
Back
surface
51 - 255
76
90
O
TC2 HEAVY CL SPX
Color
Heavy
paper
Front
surface
51 - 255
83
83
P
TC2 HEAVY CL DPX
Back
surface
51 - 255
76
76
Q
TC2 HEAVY BW SPX
Black/
White
Front
surface
51 - 255
69
69
R
TC2 HEAVY BW DPX
Back
surface
51 - 255
69
69