MX-3114N SIMULATION 6 – 50
List of destination groups
43-22
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the environment correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-4) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
Correction value: -49 - +49, Input value: Actually inputted value (1 -
99)
* Items PLAIN BW DUP APP CNT LL/ PLAIN CL DUP APP CNT LL: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
C change
Code descriptions
TH_LM
Fusing thermistor main (Back surface of paper)
HL_LM
Heater lamp main (Heat roller for back surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Group
Destination
Group A
JAPAN
-
-
-
-
-
Group B
U.S.A
CANADA
INCH
-
-
-
Group C
AB_B
EUROPE
U.K.
AUS.
AB_A
CHINA
Correction value
-49
-25
-5
0
Input value
1
25
45
50
Item/Display
Content
Setting
range
Default
value
A
HL_UM PLAIN BW DUP LL
Correction value for upper TH_UM Black-White plain paper duplex under LL environment
1 - 99
55
B
HL_LM PLAIN BW DUP LL
Correction value for lower TH_LM Black-White plain paper duplex under LL environment
1 - 99
55
C
HL_US PLAIN BW DUP LL
Correction value for upper TH_US Black-White plain paper duplex under LL environment
1 - 99
55
D
PLAIN BW DUP APP CNT LL
Correction value for applying number of sheets in Black-White plain paper duplex under LL
environment
1 - 99
50
E
HL_UM PLAIN CL DUP LL
Correction value for upper TH_UM Color plain paper duplex under LL environment
1 - 99
55
F
HL_LM PLAIN CL DUP LL
Correction value for lower TH_LM Color plain paper duplex under LL environment
1 - 99
55
G
HL_US PLAIN CL DUP LL
Correction value for upper TH_US Color plain paper duplex under LL environment
1 - 99
55
H
PLAIN CL DUP APP CNT LL
Correction value for applying number of sheets in Color plain paper duplex under LL environment
1 - 99
50
I
HL_UM HEAVY BW DUP LL
Correction value for upper TH_UM set value in Black-White heavy paper duplex under LL
environment
1 - 99
55
J
HL_LM HEAVY BW DUP LL
Correction value for lower TH_LM set value in Black-White heavy paper duplex under LL environment
1 - 99
55
K
HL_US HEAVY BW DUP LL
Correction value for upper TH_US set value in Black-White heavy paper duplex under LL
environment
1 - 99
55
L
HEAVY BW DUP APP CNT LL
Correction value for applying number of sheets in Black-White heavy paper duplex under LL
environment
1 - 99
50
M
HL_UM HEAVY CL DUP LL
Correction value for upper TH_UM set value in Color heavy paper duplex under LL environment
1 - 99
55
N
HL_LM HEAVY CL DUP LL
Correction value for lower TH_LM set value in Color heavy paper duplex under LL environment
1 - 99
55
O
HL_US HEAVY CL DUP LL
Correction value for upper TH_US set value in Color heavy paper duplex under LL environment
1 - 99
55
P
HEAVY CL DUP APP CNT LL
Correction value for applying number of sheets in Color heavy paper duplex under LL environment
1 - 99
50
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_LM
Fusing thermistor main (Back surface of paper)
HL_LM
Heater lamp main (Heat roller for back surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)