MX-3114N SIMULATION 6 – 57
44-9
Purpose
Operation data display
Function (Purpose)
Used to display the result data of the high
density process control operation.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
Select a target display mode with [CPY/PRN], [OTHER] keys.
Mode
Item/Display (*: Correction value)
Content
Display range
Default
value
CPY/PRN
P (PROCON)
BLACK : GB ***/*** DV ***/***
High density process control mode
GB/DV data (KCMY)
(Output voltage level/base voltage level)
GB: 150 - 850
DV: 0 - 600
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N(M)
(NORMAL
(MIDDLE))
BLACK : GB ***/*** DV ***/***
Medium speed print mode
GB/DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 0 - 600
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N(L)
(NORMAL
(LOW))
BLACK : GB ***/*** DV ***/***
Low speed print mode
GB/DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 0 - 600
GB: 600
DV: 400
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
OTHER
TN/TC
TN HUD AREA
Toner density correction humidity area
1 - 8
4
TN HUD DATA
Toner density correction humidity AD value
0 - 1023
0
TC TMP AREA
Transfer correction temperature area
1 - 9
4
TC TMP DATA
Transfer correction temperature AD value
0 - 1023
0
TC HUD AREA
Transfer correction humidity area
1 - 9
4
TC HUD DATA
Transfer correction humidity AD value
0 - 1023
0
MD HUD AREA
Membrane decrease correction humidity area
1 - 8
4
MD HUD DATA
Membrane decrease correction humidity AD value
0 - 1023
0
DRUM
MD K STEP
Drum membrane decrease correction STEP level
(KCMY)
0 - 4
0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER
Membrane decrease drum traveling distance area
(KCMY)
0 - 20
0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
OTHER
LIFE
MD K REVISE(LIFE) : L *** M ***
MC grid correction voltage level (for the drum
membrane decrease) (KCMY)
0 - 255
0
MD C REVISE(LIFE) : L *** M ***
MD M REVISE(LIFE) : L *** M ***
MD Y REVISE(LIFE) : L *** M ***
EV
MD K REVISE(EV) : L *** M ***
MC grid voltage correction level (for the
environment) (KCMY)
0 - 255
0
MD C REVISE(EV) : L *** M ***
MD M REVISE(EV) : L *** M ***
MD Y REVISE(EV) : L *** M ***
ALL
MD K REVISE(ALL) : L *** M ***
MC grid voltage correction level (for the drum
membrane decrease) (KCMY)
0 - 255
0
MD C REVISE(ALL) : L *** M ***
MD M REVISE(ALL) : L *** M ***
MD Y REVISE(ALL) : L *** M ***
LD
MD K REVISE(LD) : L *** M ***
Laser power correction level (for the drum
membrane decrease) (KCMY)
0 - 255
0
MD C REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
DL
MD K REVISE COL (DL): L *** M ***
Discharge lamp correction level (%) (for the drum
membrane decrease)
0 - 100
70
MD C REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
DL EV
MD K REVISE COL (DL EV): L *** M ***
Discharge lamp correction level (%) (for the
environment)
-100 - 100
0
MD C REVISE COL (DL EV): L *** M ***
MD M REVISE COL (DL EV): L *** M ***
MD Y REVISE COL (DL EV): L *** M ***
CRUM
DESTINATION
CRUM destination (Main unit data)
-
-
MODEL TYPE
Machine model type
0 - 1
0
CRUM DEST_K
CRUM destination (CRUM data)
-
-
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT
PROCON COUNT HV
High density process control number of executions
0 - 99999999
0
PROCON COUNT HT
Halftone process control number of executions
0 - 99999999
0