MX-3114N OPERATIONAL DESCRIPTIONS 13 – 58
12. Fan and filter
The machine is provided with the following fan to discharge air from the process section and cool the fusing section and the power unit.
The flow of air is as shown in the figure below.
The machine is provided with the following filter to remove ozone generated in the process section.
Filter process fan motor 1 produces an air flow to generate a difference in the air pressure between inside outside of the developing unit, pre-
venting toner from splashing from the open port of the developing unit.
The toner filter prevents toner from leaking from the slit caused by this difference in air pressure.
Signal name
Name
Function/Operation
FUFM
Fusing cooling fan
Prevents heat generated in the fusing section from lowing into the toner cartridge and the paper exit section.
POFM
Paper exit cooling fan
Cools the fusing section and the paper exit section.
POFM2
Paper exit cooling fan
Cools the fusing section and the paper exit section.
PROFM
Process fan motor 1
Blows air to the main charger and the PTC unit to promote discharging of ozone generated.
PROFM2
Process fan motor 2
Discharges ozone generated in the main charger and the PTC unit, and cools the developing unit.
PSFM
Power cooling fan motor
Cools the power unit.
No.
Name
Function/Operation
1
Toner filter
Prevents toner splash.
2
Ozone filter
Absorbs ozone generated in the image process section.
02/&-
02/&-
03&-
0/&-
&5&-