21 April 1989
2.3 CHARGE CORONA POWER PACK
The circuit operation for the charge corona begins with the input of 24 volts to
the power pack at CN1-1. This power supply is used for the high voltage
corona.
The charge corona turns on 0.1 seconds after the Start key is pressed.
A LOW signal from the I/O control board (at CN1-3) energizes the power
pack. The OFF timing is the same as the scanner return timing.
The grid voltage is also applied by the power pack. The voltage for the ID
sensor grid is -560 volts. This ID sensor grid is applied from 0.1 to 0.59
seconds after the Start key is pressed.
The voltage for the image grid changes depends on the combination of G0 -
G3 (Vrp/Vsg).
2-6
Summary of Contents for FT4460
Page 1: ...RICOH R I C O H F T 4 4 6 0 RICOH COMPANY LTD...
Page 19: ...SECTION 1 OVERALL M A C H I N E INFORMATION...
Page 29: ...28 February 1989 3 COPY PROCESSES AROUND THE DRUM...
Page 30: ...28 February 1989 4 FUNCTIONAL OPERATION 1 10...
Page 38: ...28 February 1989 7 MECHANICAL COMPONENT LAYOUT...
Page 49: ...SECTION 2 DETAILED SECTION D E S C R I P T I O N S...
Page 136: ...Section 2 Timing Chart following page...
Page 137: ......
Page 138: ...S E C T I O N 3...
Page 158: ...SERVICE T A B L E S...
Page 212: ...REPLACEMENT AND...
Page 334: ...SECTION 12...
Page 399: ......
Page 411: ......
Page 412: ......
Page 413: ......