21 April 1989
6.10 GRID VOLTAGE ADJUSTMENT (SP Mode #9-2 and 3)
Standard value (V)
Adjusting VR
SP Mode
Standard grid voltage
-920 ± 18V
VR3
#9-2
ID sensor grid voltage
-560 ± 10V
VR4
#9-3
1. Remove the rear cover and lower the I/O control board.
2. Set the multimeter range at DC 1500V and connect the probe to terminal
[G] .
3. Turn ON DIP switch 1 - 4.
Adjustment of standard grid voltage
a) Turn on the main switch.
b) Set SP Mode #9-2 as shown.
c) Adjust VR3 of the CC/TC/Bias power pack to obtain the standard
voltage.
(Adjustment of ID sensor grid voltage)
a) Set SP Mode #9-3 as shown.
b) Adjust VR4 of the CC/TC/Bias power pack to obtain the standard
voltage. Then, press the clear stop key.
c) Turn OFF DIP switch 1 - 4.
5-89