28 February 1989
1.19 UNFUSED CORY IMAGE
- Phenomenon -
Solid image rubs off easily.
- Possible Causes -
1. Nip width is too narrow.
2. Fusing temperature is too low.
3. Thermistor malfunction
- Actions -
1. Adjust the position of the pressure spring in the fusing unit.
Nip width Standard Value:
Center = 3.3 mm
Front
Rear } Deviation between the front and the rear is within 0.3 mm.
C h e c k P o s i t i o n
F e e d D i r e c t i o n
N i p W i d t h
2. Replace the spring if the problem is not solved.
Combinations of hooks
Nip width
3 . 0 ± 0 . 3 m m
3.3 ± 0.3 mm *
3.6 ± 0.3 mm
* Standard setting