21 April 1989
2.10.2 Measurement (SP Mode #59)
Manual ID setting level
ADS setting
— ADS adjustment mode (SP#34) is set to “0” or “2”.
- - - A D S a d j u s t m e n t m o d e ( S P # 3 4 ) i s s e t t o “ 1 ” .
NOTE: A maximum of 10% error may occur in bias value in the
measurement by Beckman or by monitor display.
1. Measurement by SP mode (bias voltage display):
a) Remove DIP switch cover [A] and turn DIP switches 1 - 1
and 1 - 4 ON.
b) Enter the bias voltage mode with the numeric keys.
c) The voltage is displayed on the magnification ratio indicator.
d) Press the Clear/Stop key and turn the DIP switches 1 - 1
and 1 - 4 OFF.
5-41