21 April 1989
4.16 REGISTRATION ADJUSTMENT (SP Mode #42)
Standard Setting: 8 (0 ± 2.0 mm)
1. Remove the DIP switch cover [A] and turn DIP switch 1 - 4 ON.
2. Enter registration adjusting mode with the numeric keys as shown above.
3. The magnification indicator [C] shows the current registration setting
(blinking).
4. Input a number from “0” to “15” with the numeric keys to adjust the
registration.
• Adjusting range from “0” (-6.4 mm) to “15” (+5.6mm) in 0.8mm
steps.
1 step = 0.8 mm
• Standard value = 0 ± 2 mm
5. Turn DIP switch 1 - 4 OFF.