28 February 1989
10. AC AND DC POWER DISTRIBUTION
The ac power supply is filtered and distributed to the fusing lamp,
heater, anticondensation heater (option), and main transformer.
drum
The transformer supplies 100 volts to the cooling fan, fusing fan, exposure
lamp, main motor, and sorter (option). The dc power supply board receives
100 Vac from the main transformer. This voltage is rectified and regulated to
24 and 5 volts respectively. It is distributed to the ac drive board, I/O control
board, system control board, ADF, and the power packs. Vpp is an isolated
supply.
The I/O control board and system control board supply voltage to the paper
feed board, date printer (option), editor
duplex/overlay unit (option).
The LCT has a separate AC power supply,
VCC (5Vdc) from the paper feed board.
board (option), and the multi
but receives VAA (24 Vdc) and
1-27
Summary of Contents for FT4460
Page 1: ...RICOH R I C O H F T 4 4 6 0 RICOH COMPANY LTD...
Page 19: ...SECTION 1 OVERALL M A C H I N E INFORMATION...
Page 29: ...28 February 1989 3 COPY PROCESSES AROUND THE DRUM...
Page 30: ...28 February 1989 4 FUNCTIONAL OPERATION 1 10...
Page 38: ...28 February 1989 7 MECHANICAL COMPONENT LAYOUT...
Page 49: ...SECTION 2 DETAILED SECTION D E S C R I P T I O N S...
Page 136: ...Section 2 Timing Chart following page...
Page 137: ......
Page 138: ...S E C T I O N 3...
Page 158: ...SERVICE T A B L E S...
Page 212: ...REPLACEMENT AND...
Page 334: ...SECTION 12...
Page 399: ......
Page 411: ......
Page 412: ......
Page 413: ......