28 February 1989
2.18 CODE #93
- Phenomenon -
SC #93: System control board and I/O control board are disconnected.
- Possible Causes -
1. Poor connection of the harness connectors between the system control
board and I/O control board.
2. I/O control board malfunction
3. System control board malfunction
- Actions -
1. Check the connections between the system control board and the I/O
control board.
System control board: CN101
I/O control board: CN301
2. Replace the I/O control board.
3. Replace the system control board
2.19 CODE #94
- Phenomenon -
SC #94: Communication failure between the editor main board and the
system control board
- Possible Causes -
1.
2.
3.
Poor connection of the harness connectors between the system control
board and the editor main board
Editor main board malfunction
System control board malfunction