21 April 1989
6.11.1 Transfer Current Measurement (SP Mode #9-5)
Standard Value: DC -18.0 ± 1.5µA
1. Put the drum shoe [A] on the center of the drum shaft with the curved sur-
face facing the transfer corona wire [B].
2. Set the range of the multimeter to DC200µA.
3. Make sure that the release lever of the transport unit is in the up position.
4. Turn on the main switch.
5. Enter SP Mode #9-5 as shown.
6. Adjust the VR-2 of the CC/TC/Bias power pack to obtain the standard
value.
7. Press the Clear/Stop key and turn off the main switch.
5-91