21 April 1989
6.11.2 Separation Corona Current Measurement (SP Mode #9-7)
Standard Value:
AC 44 ± 2.0µA
DC +1.5 ± 1.5µA
NOTE: Turn off the main switch before changing the multimeter setting.
1. Shift the drum shoe [A] slightly to the left so that the distance between the
stay of the pick-off pawl and the edge of the drum shoe is 10 mm (as
shown). Then, lock the drum shoe in place.
2. Set the multimeter range to AC200µA.
3. Turn on the main switch.
4. Enter SP Mode 9-7 as shown:
5. Adjust the VR AC of the separation power pack to obtain the standard
value.
6. Press the Clear/Stop key and turn off the main switch.
7. Set the multimeter range to DC200µA.
8. Turn on the main switch and enter SP Mode #9-7 as shown.
9. Adjust VR DC of the separation power pack to obtain the standard value.
Press the Clear/Stop key. Repeat steps “4 to 9” and adjust the AC and
DC currents to within the standard.
5-92