28 February 1989
6.3 CHARGE CORONA HEIGHT ADJUSTMENT
NOTE: Adjust the charge corona height after cleaning the optics section.
Adjust the charge corona height to achieve even gradation [A] using an OS-
A3 test chart as following order.
1) Place the charge corona unit on a flat surface with the grid side [B] down.
2) Measure the height of the rear side of the corona wire [C].
3) Adjust the front side to be eqal to the rear measurement.
NOTE: Measurement should be approximately 9 mm.
5-80
Summary of Contents for FT4460
Page 1: ...RICOH R I C O H F T 4 4 6 0 RICOH COMPANY LTD...
Page 19: ...SECTION 1 OVERALL M A C H I N E INFORMATION...
Page 29: ...28 February 1989 3 COPY PROCESSES AROUND THE DRUM...
Page 30: ...28 February 1989 4 FUNCTIONAL OPERATION 1 10...
Page 38: ...28 February 1989 7 MECHANICAL COMPONENT LAYOUT...
Page 49: ...SECTION 2 DETAILED SECTION D E S C R I P T I O N S...
Page 136: ...Section 2 Timing Chart following page...
Page 137: ......
Page 138: ...S E C T I O N 3...
Page 158: ...SERVICE T A B L E S...
Page 212: ...REPLACEMENT AND...
Page 334: ...SECTION 12...
Page 399: ......
Page 411: ......
Page 412: ......
Page 413: ......