28 February 1989
1.17 APS VOLTAGE ADJUSTMENT (SP Modes #61 & #62)
Standard Value: 2.8 ± 0.1V
1. Place a few sheets of A3 (LDG) size paper on the exposure glass.
2. Remove the DIP switch cover [A] and turn DIP switch 1 - 4 ON.
3. Enter the APS length voltage adjusting mode using the numeric keys (SP
Mode #61).
4. Remove the rear cover.
5. Press the Start key and use VR302 (I/O control PCB) to adjust the peak
value on the magnification display [B] to 2.8 ± 0.1V.
6. Press the Clear/Stop key.
7. Enter the APS width voltage adjusting mode using the numeric keys (SP
Mode #62).
8. Press the Start key and use VR301 (I/O control PCB) to adjust the peak
value on the magnification display [B] to 2.8 ± 0.1V.
NOTE: Adjustment is required when the I/O control PCB and/or the system
control board are replaced.
5-25