23 May 1989
6.9 CHARGE CORONA CURRENT ADJUSTMENT (SP Mode
#9-2)
Standard Value: -400 ± 2µA
1. Turn off the main switch.
2. Remove the rear cover (4 screws).
3. Lower the I/O control board [A].
4. Disconnect the charge corona terminal [M] from the CC/TC/Bias power
pack.
5. Connect the multimeter leads as shown, and measure the main corona
current.
6. Turn DIP switch 1 - 4 ON.
7. Turn on the main switch, and select SP Mode #9-2 as shown.
8. Adjust the charge corona current to -400 ± 2µA by turning VR1 on the
CC/TC/Bias power pack.
NOTE: To avoid possible shock hazard it is recommended to attach an
aligator clip to the charge corona terminal [M] then secure positive
meter lead with the other end of the clip.
5-88