28 February 1989
7.9 FUSING TEMPERATURE ADJUSTMENT (SP Mode #49)
Normal Setting: 185°C
The fusing temperature can be adjusted within the range of 175°C to 190°C
(in 1°C steps) according to the following procedure:
1. Remove the DIP switch cover [A], and turn ON DIP switch 1 - 4.
2. Enter the fusing temperature adjustment mode using the numeric keys
(SP Mode #49).
3. The current temperature setting blinks in the magnification display. Enter
the new temperature setting with the numeric keys.
4. Turn OFF DIP switch 1 - 4.
Adjustment is required in the following conditions:
a) Fusing error has occurred
b) Fusing thermistor replacement
c) I/O control PCB replacement
d) AC drive PCB replacement.
5-101