2.13 HIGHLIGHT COLOR DENSITY AMOUNT (SP Mode #86)
Normal Set Value = 4 (-200V)
1. Remove the DIP switch cover [A] and turn DIP switch 1 - 4 ON.
2. Enter the highlight color density adjustment mode with the numeric keys
(SP Mode #86).
3. Numerals displayed in the magnification ratio indicator blink.
4. Input a number from “1” to “7” with the numeric keys to adjust the bias volt-
age, then press the Enter key.
5. Turn DIP switch 1 - 4 OFF.
NOTE: Adjust the bias for each color (for each color development unit).