
[Reload Permit Setting]
Specifies the settings of the reload permit for cold temperature in BW mode 2.
103 Temp.:Delta:Cold:BW2:Center
*ENG
[0 to 200 / 5 / 1 deg/step]
104 Temp.:Delta:Cold:BW2:End
*ENG
[0 to 200 / 5 / 1 deg/step]
105 Temp.:Delta:Cold:BW2:Press
*ENG
[0 to 200 / 100 / 1 deg/step]
[Reload Permit Setting]
Specifies the setting of the forced reload permit for cold temperature in BW mode 2.
106 Forced Reload Time:Cold:BW2
*ENG
[0 to 100 / C3c: 14, C3d: 20 / 1 sec/
step]
[Reload Permit Setting]
Specifies the settings of the reload permit for low temperature.
151 Temp.:Delta:Low Temp.:Center
*ENG
[0 to 200 / 5 / 1 deg/step]
152 Temp.:Delta:Low Temp.:End
*ENG
[0 to 200 / 5 / 1 deg/step]
153 Temp.:Delta:Low Temp.:Press
*ENG
[0 to 200 / C3c: 40, C3d: 33 / 1 deg/
step]
[Reload Permit Setting]
Specifies the setting of the forced reload permit for low temperature.
154 Forced Reload Time:Low Temp.
*ENG
[0 to 100 / 60 / 1 sec/step]
1101
[Reload Permit Setting]
Specifies the settings of the reload permit for cold temperature.
201
Temp .:Delta:Cold:Center:
FIN-less/ADF-less
*ENG
[0 to 200 / 5 / 1 deg/step]
202
Temp .:Delta:Cold:End:
FIN-less/ADF-less
*ENG
[0 to 200 / 5 / 1 deg/step]
203
Temp .:Delta:Cold:Press:
FIN-less/ADF-less
*ENG
[0 to 200 / C3c: 67, C3d: 36 / 1 deg/
step]
[Reload Permit Setting]
Specifies the setting of the forced reload permit for cold temperature.
Main SP Tables-1
51
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...