007 Current Temp. FC: Display
*ENG
Displays the current temperature.
[0 to 100 / - / 1 deg/step]
008
Current Relative Humidity FC:
Display
*ENG
Displays the current relative humidity.
[0 to 100 / - / 1%RH/step]
009
Current Absolute Humidity
FC: Display
*ENG
Displays the absolute humidity.
[0 to 100 / - / 0.01 g/m
3
/step]
010
Previous Environmental Bk:
Display
*ENG
Displays the previous environmental condition,
which is measured in absolute humidity.
[1 to 5 / - / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
011 Previous Temp. Bk: Display
*ENG
Displays the previous temperature.
[0 to 100 / - / 1 deg/step]
012
Previous Relative Humidity
Bk: Display
*ENG
Displays the previous relative humidity.
[0 to 100 / - / 1%RH/step]
013
Previous Absolute Humidity
Bk: Display
*ENG
Displays the previous absolute humidity.
[0 to 100 / - / 0.01 g/m
3
/step]
2015
[Charge AC Adj: Result]
Displays a result of the AC charge adjustment.
001 Bk
*ENG
[0 to 9 / 0 / 1 /step]
0: Success
1: Out of tolerance range
2: Out of adjustable range
3: Adjustment incompleted
002 M
*ENG
003 C
*ENG
004 Y
*ENG
2101
[Color Registration Correction] FA
These values are the parameters for the automatic line position adjustment and are
adjusted at the factory. However, you must input a value for SP2101-001 after replacing
the laser optics housing unit. For details, see "Laser Optics Housing Unit" in the
"Replacement and Adjustment" section. The value should be provided with the new laser
optics housing unit.
5. System Maintenance
432
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...