• Auto Off: 1 min.
• The machine goes to Off mode after 1 minute. Low Power mode is not used.
Return to Stand-by Mode
Low Power Mode
The recovery time depends on the model and the region.
• C3c: 15 sec. or less
• C3d: 20 sec. or less
Off/Sleep Mode
Recovery time.
• C3c: 20 sec. or less
• C3d: 30 sec. or less
Recommendation
We recommend that the default settings should be kept.
• If the customer requests that these settings should be changed, please explain that their energy
costs could increase, and that they should consider the effects on the environment of extra energy
use.
• If it is necessary to change the settings, please try to make sure that the Auto Off timer is not too
long. Try with a shorter setting first, such as 30 min., then go to a longer one (such as 60 min.) if the
customer is not satisfied.
• If the timers are all set to the maximum value, the machine will not begin saving energy until 240
minutes has expired after the last job. This means that after the customer has finished using the
machine for the day, energy will be consumed that could otherwise be saved.
• If you change the settings, the energy consumed can be measured using SP8941, as explained
below.
Energy Save Effectiveness
SP 8941 (Machine Status) keeps a record of the amount of time that the machine spends in each mode.
• 8941-001: Operating mode
• 8941-002: Standby mode
• 8941-004: Low power mode
• 8941-005: Off/sleep mode
7. Energy Saving
916
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...