001
Sets the alarm to sound for the specified jam level (document misfeeds are not included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the error alarm
counter decreases by "1" when an SC is not detected during a set number of copied
sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 -
*CTL
[0 to 255 / C2.5c: 50, C2d: 60 / 100
copies /step]
5508*
[CC Call]
*CTL
-
001*
Jam Remains
0: Disable, 1: Enable
Enables/disables initiating a call for an unattended paper jam.
002*
Continuous Jams
0: Disable, 1: Enable
Enables/disables initiating a call for consecutive paper jams.
003*
Continuous Door Open
0: Disable, 1: Enable
Enables/disables initiating a call when the front door remains open.
011*
Jam Detection: Time Length
[3 to 30 / 10 / 1 minute /step]
Sets the time a jam must remain before it becomes an “unattended paper jam”. This
setting is enabled only when SP5508-004 is set to "1".
012*
Jam Detection: Continuous Count
[2 to 10 / 5 / 1 /step]
Sets the number of consecutive paper jams required to initiate a call. This setting is
enabled only when SP5508-004 is set to "1".
Main SP Tables-5
231
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...