005 Job Low Temp. Correction
*ENG
[0 to 100 / 5 / 0.1 deg/step]
006 Job High Temp. Correction
*ENG
[0 to 100 / 0 / 0.1 deg/step]
007
Job Low Temp.
Correction:Sp.
*ENG
[0 to 100 /10 / 0.1 deg/step]
008
Job High Temp.
Correction:Sp.
*ENG
[0 to 100 / 0 / 0.1 deg/step]
011 Standard Environment Temp. *ENG
[10 to 30 / 23 / 1 deg/step]
1113
[Curl Correction]
001
Execute Pattern
*ENG
[0 to 2 / 0 / 1 /step]
0: Off, 1: On (No Decurl), 2: On
Selects the curl correction type.
002
Humidity:Threshold:M-humid *ENG
[0 to 100 / 1 / 1 %/step]
Specifies the threshold between low and middle humidity.
003
Humidity:Threshold:H-humid
*ENG
[0 to 100 / 65 / 1 %/step]
Specifies the threshold between middle and high humidity.
004
Permit Temp.:Delta:Press:M-
humid
*ENG
[0 to 200 / 40 / 1 deg/step]
Specifies the threshold temperature for the curl control in middle humidity.
005
Permit Temp.:Delta:Press:H-
humid
*ENG
[0 to 200 / 30 / 1 deg/step]
Specifies the threshold temperature for the curl control in high humidity.
006
Permit Temp.:Delta:Press:M-
humid:No Decurl
*ENG
[0 to 200 / 30 / 1 deg/step]
Specifies the threshold temperature for the no curl control in middle humidity.
007
Permit Temp.:Delta:Press:H-
humid:No Decurl
*ENG
[0 to 200 / 20 / 1 deg/step]
Specifies the threshold temperature for the no curl control in high humidity.
5. System Maintenance
396
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...