No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
498
C
Temperature and humidity sensor error 2
• The thermistor output of the temperature sensor was not within the prescribed
range (more than 0.5 V to less than 3.0 V).
• The thermistor output of the humidity sensor was not within the prescribed
range (less than 2.4 V).
• Temperature and humidity sensor harness disconnected, loose, defective
• Temperature and humidity sensor defective
1. Check the connector and harness.
2. Replace the temperature/humidity sensor.
Service Call Tables – 5
SC5xx: Paper Feed and Fusing
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
501
B
Paper Tray 1 error
502
B
Paper Tray 2 error
Service Call
803
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...