067
CERT:Up State
Displays the status of the certification update.
0
The certification used by RCG-N is set correctly.
1
The certification request (setAuthKey) for update has been received from the GW
URL and certification is presently being updated.
2
The certification update is completed and the GW URL is being notified of the
successful update.
3
The certification update failed, and the GW URL is being notified of the failed
update.
4
The period of the certification has expired and new request for an update is being
sent to the GW URL.
11
A rescue update for certification has been issued and a rescue certification setting
is in progress for the rescue GW connection.
12
The rescue certification setting is completed and the GW URL is being notified of
the certification update request.
13
The notification of the request for certification update has completed successfully,
and the system is waiting for the certification update request from the rescue GW
URL.
14
The notification of the certification request has been received from the rescue GW
controller, and the certification is being stored.
15
The certification has been stored, and the GW URL is being notified of the
successful completion of this event.
16
The storing of the certification has failed, and the GW URL is being notified of the
failure of this event.
17
The certification update request has been received from the GW URL, the GW
URL was notified of the results of the update after it was completed, but an
certification error has been received, and the rescue certification is being
recorded.
18
The rescue certification of No. 17 has been recorded, and the GW URL is being
notified of the failure of the certification update.
5. System Maintenance
578
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...