002 Page: PCU: Bk
*ENG -
003 Page: PCU: M
004 Page: PCU: C
005 Page: PCU: Y
006 Page: Development Unit: Bk
007 Page: Development Unit: M
008 Page: Development Unit: C
009 Page: Development Unit: Y
010 Page: Developer: Bk
*ENG -
011 Page: Developer: M
012 Page: Developer: C
013 Page: Developer: Y
014 Page: Image Transfer
015 Page: Cleaning Unit
016 Page: Fusing Unit
017 Page: Paper Transfer Unit
018 Page: Toner Collection Bottle
019 Page: Fusing Roller
020 Page: Pressure Roller
Displays the number of revolutions of motors or clutches for each current maintenance
unit.
[ 0 to 9999999 / 0 / 1 revolution/step ]
When a unit is replaced, and SP7804-xxx is executed, the current PM counter value is
moved to the PM Counter - Previous (SP7-906-11 to 20) and is reset to “0”. The total
number of revolutions made with the last unit replaced can be checked with SP7-906-11
to 20.
021 -
*ENG
5. System Maintenance
634
Summary of Contents for AP-C3
Page 1: ...Model AP C3 Machine Code D143 D144 Field Service Manual January 2012 Subject to change...
Page 2: ......
Page 24: ...22...
Page 26: ...Product Overview Component Layout 1 Product Information 24...
Page 36: ...1 Product Information 34...
Page 130: ...11 Reassemble the machine 2 Installation 128...
Page 158: ...2 Installation 156...
Page 249: ...21 Pulley A timing belt 22 Gear unit A x 8 Drive Unit 247...
Page 259: ...5 Disconnect the connector A x 1 x 1 6 Duplex by pass motor bracket A x 2 Drive Unit 257...
Page 268: ...6 Development clutch K A x 1 4 Replacement and Adjustment 266...
Page 323: ...5 Remove the controller box stay A x 4 6 IOB bracket A x 4 x All Electrical Components 321...
Page 336: ...2 Controller board A x 7 x 3 4 Replacement and Adjustment 334...
Page 366: ...3 Remove the bracket A x 1 x 1 4 Release the harness A x 1 4 Replacement and Adjustment 364...
Page 880: ...6 Troubleshooting 878...
Page 890: ...Flow Chart for the Toner End Recovery Error 6 Troubleshooting 888...
Page 908: ...Sensor Locations 6 Troubleshooting 906...
Page 922: ...6 Duplex with combine mode SP 8421 005 pages 7 Energy Saving 920...
Page 923: ...Model AP C3 Machine Code D143 D144 Appendices January 2012 Revised...
Page 924: ......
Page 928: ...4...
Page 960: ...1 Appendices 36...
Page 1330: ...1106 1 Toner Limit Value CTL 100 to 400 260 1 step 3 SP Mode Tables 406...