![Parker AC890PX Series Product Manual Download Page 70](http://html1.mh-extra.com/html/parker/ac890px-series/ac890px-series_product-manual_755704070.webp)
Safe Torque Off
4-4
AC890PX AC Drive
Alignment to European Standards
EN ISO13849-1:2008
(Safety of machinery – Safety-related parts of control systems)
STO aligns to the following aspects of this standard:
Architecture according to Category 3:
I1
L1
O1
I2
L2
O2
im1
im2
im1a
im2a
C
m1
m2
P3
P2
P1
im1b
Im2b
im1b
im1b
Im2b
Im2b
Solid lines represent the STO control paths.
Dashed lines represent reasonably practicable fault detection.
Key:
I1, I2 = user terminal
L1, L2 = logic
O1, O2 = methods of enabling or disabling output power devices
P1, P2, P3 = output power devices
i
mxy
=
interconnecting means
m
x
= monitoring
c
= cross monitoring
Summary of Contents for AC890PX Series