Programming
D-38
AC890PX AC Drive
Parameter Descriptions
ENCODER TYPE
PREF: 71.04
Default: 3
Range: See below
This parameter defines the type of encoder being used.
Enumerated Value : Type
0 : QUADRATURE
single-ended pulse encoder
1 : CLOCK/DIR
single-ended pulse encoder
2 : CLOCK
single-ended pulse encoder
3 : QUADRATURE DIFF
differential pulse encoder
4 : CLOCK/DIR DIFF
differential pulse encoder
5 : CLOCK DIFF
differential pulse encoder
6 : SINCOS INC
sin/cos encoder
7 : ABS ENDAT ST
single turn endat absolute encoder
8 : ABS ENDAT MT
multi-turn endat absolute encoder
9 : RESOLVER absolute encoder
Note that if an absolute endat encoder is used, the encoder MUST be wired exactly as specified. If not, it will fail to calibrate
the absolute position and an error will result when the drive is started. Its status can be viewed via the parameter CALIBRATN
STATUS.
PMAC motor control needs to work with an absolute position. Using absolute encoders is preferred but using relative encoder
is possible with heavy constraints:
-
at each power up, an init sequence is needed to align the Zero encoder position to the motor Back EMF. For this
purpose, the motor should be free of rotation, without any load or friction on its shaft.
As described, absolute encoders are :
-
single turn or multi turn endat encoder
-
resolver
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...