80.02
MODE
AUTOTUNE
ENUM
0 : STATIONARY
1 : ROTATING
2 : SPD LOOP
ROTATNG
3 : SPD LOOP STATNRY
ROTATING
rw
80.03
TEST DISABLE
AUTOTUNE
WORD
0000 to FFFF
0000
rw
80.09
ACTIVE
AUTOTUNE
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
80.20
SPD LOOP
BNDWDTH
AUTOTUNE
REAL
0.0 to 500.0 Hz
2.0 Hz
rw
80.23
SPD MAX TORQUE
AUTOTUNE
REAL
0.0 to 500.0 %
50.0 %
rw
80.24
SPD MAX SPEED
AUTOTUNE
REAL
15.0 to 100.0 %
50.0 %
rw
81.01
VOLTAGE MODE
VOLTAGE
CONTROL
ENUM
0 : NONE
1 : FIXED
2 : AUTOMATIC
NONE
rw
81.03
BASE VOLTS
VOLTAGE
CONTROL
REAL
0.00 to 115.47 %
100.00 %
rw
82.01
CURRENT LIMIT
CURRENT LIMIT
REAL
0.00 to 300.00 %
150.00 %
rw
82.02
REGEN LIM
ENABLE
CURRENT LIMIT
BOOL
0 : FALSE
1 : TRUE
TRUE
rw
82.03
ACTUAL CUR LIMIT
CURRENT LIMIT
REAL
_.xx
150.00 %
ro
Output
83.01
POS TORQUE LIM
TORQUE LIMIT
REAL
-300.00 to 300.00 %
150.00 %
rw
83.02
NEG TORQUE LIM
TORQUE LIMIT
REAL
-300.00 to 300.00 %
-150.00 %
rw
83.03
MAIN TORQUE LIM
TORQUE LIMIT
REAL
0.00 to 300.00 %
150.00 %
rw
83.04
SYMMETRIC LIM
TORQUE LIMIT
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
83.05
ACTUAL POS LIM
TORQUE LIMIT
REAL
_.xx
0.00 %
ro
Output
83.06
ACTUAL NEG LIM
TORQUE LIMIT
REAL
_.xx
0.00 %
ro
Output
83.07
FAST STOP T-LIM
TORQUE LIMIT
REAL
0.00 to 300.00 %
150.00 %
rw
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...