Notes
27.09
MOTOR POLES
MOTOR
INDUCTION
ENUM
0 : 2 POLE
1 : 4 POLE
2 : 6 POLE
3 : 8 POLE
4 : 10 POLE
5 : 12 POLE
4 POLE
rw
27.10
POWER FACTOR
MOTOR
INDUCTION
REAL
0.50 to 0.99
0.86
rw
3
27.11
OVERLOAD
MOTOR
INDUCTION
REAL
1.0 to 5.0
2.0
rw
3
27.14
STATOR RES
MOTOR
INDUCTION
REAL
0.0000 to 250.0000 Ohm 0.2851 Ohm
rw
3,5
27.15
LEAKAGE INDUC
MOTOR
INDUCTION
REAL
0.00 to 300.00 mH
9.08 mH
rw
3,5
27.16
MUTUAL INDUC
MOTOR
INDUCTION
REAL
0.00 to 3000.00 mH
36.30 mH
rw
3,5
27.17
ROTOR TIME
CONST
MOTOR
INDUCTION
REAL
10.00 to 30000.00 ms
506.08 ms
rw
3,5
27.23
TOTAL INERTIA
MOTOR
INDUCTION
REAL
0.0000 to 300.0000
kgm2
0.0000 kgm2
rw
5
29.01
DEFLUX TIME
INJ BRAKING
REAL
0.1 to 20.0 s
1.0 s
rw
3,5
29.02
FREQUENCY
INJ BRAKING
REAL
1.0 to 500.0 Hz
6.0 Hz
rw
3,5
29.03
I-LIM LEVEL
INJ BRAKING
REAL
50.00 to 150.00 %
100.00 %
rw
29.04
DC PULSE
INJ BRAKING
REAL
0.0 to 100.0 s
2.0 s
rw
3,5
29.05
FINAL DC PULSE
INJ BRAKING
REAL
0.0 to 10.0 s
3.0 s
rw
3,5
29.06
DC LEVEL
INJ BRAKING
REAL
0.00 to 25.00 %
1.25 %
rw
3,5
29.07
TIMEOUT
INJ BRAKING
REAL
0.0 to 600.0 s
90.0 s
rw
29.08
BASE VOLTS
INJ BRAKING
REAL
0.00 to 115.47 %
75.00 %
rw
3,5
29.09
ACTIVE
INJ BRAKING
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...