Programming
D-240
AC890PX AC Drive
2
PREF
Name
Block
Type
Range
Default
ro\rw
Notes
124.06 DIST TO MASTER
MOVE TO MASTER REAL
_.xxxx
0.0000
ro
Output
124.08 ACTIVE
MOVE TO MASTER BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
124.09 STATE
MOVE TO MASTER ENUM
0 : RESET
1 : READY
2 : POS AQUIRE
3 : ALIGN
4 : DONE
READY
ro
Output
125.01 EMC CAPACITORS
EMC CAPACITORS ENUM
0 : CONNECTED
1 : NOT CONNECTED
CONNECTED
rw
2
126.01 BAUDRATE
CANOPEN
ENUM
0 : 125K
1 : 250K
2 : 500K
3 : 1000K
125K
ro
Output
126.02 ADDRESS
CANOPEN
INT
_
0
ro
Output
126.03 STATUS RUN
CANOPEN
ENUM
0 : STOPPED
1 : PRE-OPERATIONAL
2 : OPERATIONAL
STOPPED
ro
Output
126.04 STATUS ERROR
CANOPEN
ENUM
0 : NO ERROR
1 : WARNING LIMIT
2 : AUTOBAUD OR LSS
3 : CONTROL EVENT
4 : SYNC. ERROR
5 : BUS OFF
NO ERROR
ro
Output
126.05 HARDWARE
CANOPEN
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
126.06 BAUDRATE SOFT
CANOPEN
ENUM
0 : 125K
1 : 250K
2 : 500K
3 : 1000K
1000K
rw
126.07 ADDRESS SOFT
CANOPEN
INT
1 to 127
1
rw
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...