PREF
Name
Block
Type
Range
Default
ro\rw
Notes
158.04 ENCODER TYPE
REFERNCE
ENCODER
ENUM
0 : QUADRATURE
1 : CLOCK/DIR
2 : CLOCK
3 : QUADRATURE DIFF
4 : CLOCK/DIR DIFF
5 : CLOCK DIFF
6 : SINCOS INC
7 : ABS ENDAT ST
8 : ABS ENDAT MT
9 : RESOLVER
QUADRATURE DIFF
rw
2
158.05 OUTPUT GBOX IN
REFERNCE
ENCODER
INT
1 to 2000000000
1
rw
2
158.06 ENCODER MECH
O/S
REFERNCE
ENCODER
REAL
0.0000 to 360.0000 deg
0.0000 deg
rw
2
158.09 SHAFT POSITION
REFERNCE
ENCODER
REAL
_.xx
0.00 deg
ro
Output
158.10 LOAD POSITION
REFERNCE
ENCODER
REAL
_.xx
0.00 deg
ro
Output
158.13 CALIBRATN
STATUS
REFERNCE
ENCODER
ENUM
0 : NOT REQUIRED
1 : DRIVE NOT STOPPD
2 : MOTOR NOT STOPPD
3 : ENDAT FAULT
4 : CAL IN PROGRESS
5 : LD PSN IN PRGRSS
6 : COMPLETED
7 : CALIBRATION LOST
8 : CALIBRATN FAILED
9 : CAL WARNING
NOT REQUIRED
ro
Output
158.15 REV COUNT
REFERNCE
ENCODER
INT
_
0
ro
Output
158.22 SINCOS ENC
VOLTS
REFERNCE
ENCODER
ENUM
0 : 5V
1 : 10V
5V
rw
2
Summary of Contents for AC890PX Series
Page 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Page 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Page 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Page 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Page 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...