8-2
Keypad Menus
AC890PX AC Drive
Keypad Menus
The OPERATOR Menu
OPERATOR MENU
6911 Display
SETPOINT (xxxxxx)
Range:
—.xx %
(Fixed as PREF 101.10) Indicates target speed. This will be equal to either:
LOCAL SETPOINT, REMOTE SETPOINT, JOG SETPOINT, COMMS
SETPOINT or FIREWIRE SETPOINT.
(Refer to the REFERENCE or REFERENCE JOG function
blocks)
SPEED DEMAND
Range:
—.xx %
(Default: PREF 101.16) Indicates actual speed demand. This is the input to the Drive.
(Refer to the REFERENCE function block)
DRIVE FREQUENCY
Range:
—.xx Hz
(Default: PREF 73.04) The Drive output frequency.
(Refer to the REFERENCE function block)
MOTOR CURRENT A
Range:
—.xx A
(Default: PREF 70.13) This diagnostic contains the level of rms line current being drawn from the Drive.
(Refer to the REFERENCE function block)
TORQUE FEEDBACK
Range:
—.xx %
(Default: PREF 70.10) Shows the estimated motor torque, as a percentage of rated motor torque.
(Refer to the REFERENCE function block)
DC LINK VOLTS
Range:
—. V
(Default: PREF 70.02) This shows the voltage on the dc link capacitors.
(Refer to the REFERENCE function block)